WattBox WB-UPS-OL-2000-8 Online Double Conversion UPS 2000VA 8 Outlets
2000VA online double conversion UPS for larger AV racks, network closets, NVRs, routers, switches, control systems, and business-critical electronics. Built with 8 UPS-backed outlets, 4 always-on critical-load outlets, 4 programmable outlets, zero transfer time, pure sinewave output, LCD monitoring, USB/RS-232 management, optional SNMP, and support for up to 5 extended battery packs.
Tax excluded. Shipping calculated at checkout
Free U.S. shipping is available on orders over $499.99.
Personalized pricing may be available for a single item, multiple products, larger quantities, or competitive quotes.
Shipping Information
A tracking number is provided by email after the order has shipped. U.S. only: Orders usually process in 1 to 2 business days, with delivery typically taking 3 to 6 business days after shipment. Free shipping on orders over $499.99 For more information, please see our Shipping Policy here.
30 Day Returns & Warranty
We accept returns within 30 days of delivery for unused, uninstalled items in original packaging. Many products also include a manufacturer warranty. For more information, please see our Refund Policy here.

Official Product Resources
WB-UPS-OL-2000-8 Product Manual & Specs
View the official WB-UPS-OL-2000-8 manual for product specifications, setup details, wiring guidance, and installation reference before ordering.
Open WB-UPS-OL-2000-8 Manual PDFOpens the official PDF manual in a new tab, where you can view, save, or print the file from your browser.
WattBox WB-UPS-OL-2000-8 Online Double Conversion UPS 2000VA 8 Outlets
Product Details
High-Capacity Online Backup Power for Larger Equipment Racks
The WattBox WB-UPS-OL-2000-8 is a 2000VA online double conversion UPS designed for larger AV racks, network closets, security systems, structured wiring areas, control systems, and business-critical electronics that need continuous conditioned power.
It includes 8 built-in UPS-backed outlets. Four always-on critical-load outlets remain powered until the battery is depleted, while four programmable outlets can shut down non-critical equipment at a selected battery level to preserve additional runtime for the devices that matter most.
Best Use Cases
- Larger network closets: Helps protect routers, firewalls, gateways, switches, modems, controllers, and core network infrastructure.
- Security camera systems: A strong fit for NVRs, PoE switches, routers, storage devices, and surveillance support equipment.
- AV racks: Useful for processors, media servers, distribution gear, streamers, control systems, and suitable AV components.
- Smart home systems: Helps protect automation processors, hubs, bridges, controllers, and supporting network gear.
- Small business equipment: Good for offices, studios, retail locations, conference rooms, and critical equipment areas where unexpected shutdowns can interrupt operations.
- Longer-runtime projects: Supports compatible external battery packs when the internal battery runtime is not enough.
Who Should Buy This?
This UPS is a strong choice if you need to protect several rack devices directly and require more output capacity than the 1000VA or 1500VA models.
It makes sense when you need online double conversion, zero transfer time, pure sinewave output, 8 built-in outlets, critical-load prioritization, programmable load shedding, computer-based configuration, optional network management, and expandable runtime.
Who Should Not Buy This?
This is more UPS than most small modem, router, or desktop setups require. For a light equipment load, a smaller WattBox UPS may be easier to install and more cost-effective.
This is also not the right model if you specifically need native OvrC UPS monitoring or OvrC-based load shedding. This is the non-OvrC WB-UPS-OL model. It uses PC software, USB, RS-232, and optional SNMP for configuration and monitoring.
Do not assume that the 2000VA rating means the UPS supplies 2000W at every output voltage. At 120V, the published maximum output is 1850W. Leave additional headroom for runtime performance, future equipment, and startup behavior.
Do not connect heaters, appliances, laser printers, power tools, or other unsuitable high-draw equipment. High-current power amplifiers should also be evaluated carefully before connection.
Compatibility and Technical Notes
- UPS topology: Online double conversion for continuous inverter-supplied power.
- Capacity class: 2000VA.
- Output at 125V: Up to 2000VA / 1930W.
- Output at 120V: Up to 2000VA / 1850W.
- Output at 115V: Up to 2000VA / 1740W.
- Output at 110V: Up to 2000VA / 1640W.
- Output at 100V: Up to 1800VA / 1500W.
- Outlet count: Includes 8 built-in UPS-backed outlets.
- Critical-load outlets: Four always-on outlets remain active until the UPS battery is depleted.
- Programmable outlets: Four non-critical outlets can be programmed to turn off at a selected battery percentage using the PC utility software.
- Transfer time: Zero transfer time from AC operation to battery operation.
- Output waveform: Pure sinewave output in battery mode.
- Output voltage: Supports selectable output voltage settings from 100V through 127V AC.
- Current class: This is the 20A-class model. Confirm that the installation has a compatible circuit and receptacle before ordering.
- LCD monitoring: Displays load, runtime estimate, battery condition, input and output voltage, frequency, current, alarms, warnings, and faults.
- Local management: Includes PC software with USB and RS-232 connectivity.
- Network management: Optional SNMP support is available with compatible hardware sold separately.
- Emergency shutdown: Includes an Emergency Power Off connection for suitable installations.
- Graceful shutdown: USB communication can instruct a compatible computer to save files and shut down properly during an extended outage.
- Rack size: 2U rack-mount design.
- Dimensions: Approximately 17.24 inches wide, 3.46 inches high, and 20.08 inches deep.
- Weight: Approximately 42.99 lb with the internal batteries installed.
- Internal batteries: Uses four 12V / 9Ah sealed lead-acid batteries.
- Recharge time: Approximately 3 hours to recover to 95% internal-battery capacity under the specified charging conditions.
- Runtime expansion: Supports up to five compatible WB-UPS-EBP-18AH48V extended battery packs.
- OvrC: This model does not provide the native OvrC pairing functions of the WB-OVRC-OLUPS series.
Installation Considerations
Before ordering, calculate the total wattage of every device that will connect to the UPS. Use the published watt capacity for your selected output voltage and leave enough headroom for better runtime, future equipment, and changing loads.
For a typical 120V installation, plan around the published 1850W maximum rather than assuming the unit can continuously supply 2000W.
This is a 20A-class UPS. Confirm the available branch circuit, receptacle, power cord connection, and installation requirements before purchase. Consult a qualified electrician when a compatible circuit or receptacle must be added.
Decide which devices should use the four always-on critical-load outlets. The modem, router, firewall, main switch, NVR, storage, and control processor will usually be more important than secondary streamers, displays, and nonessential accessories.
Use the PC utility software to configure the four programmable outlets. Turning off non-critical equipment as the battery level falls can preserve more runtime for core network, security, and control devices.
Confirm that the rack provides 2U of space, at least 20.08 inches of chassis depth plus clearance for rear cables, proper ventilation, and enough structural support for the UPS and any extended battery packs.
The UPS ships with its internal battery disconnected for safety. The battery connection must be completed according to the official instructions before the UPS is placed into service.
Runtime Expectations
Runtime depends on the connected load. The official internal-battery runtime chart estimates approximately:
- 100% load: 2 minutes and 26 seconds
- 70% load: 5 minutes and 19 seconds
- 50% load: 9 minutes and 34 seconds
- 30% load: 19 minutes and 17 seconds
- 20% load: 31 minutes and 40 seconds
- 10% load: 68 minutes and 23 seconds
These figures are planning estimates rather than guaranteed runtime. Battery condition, temperature, connected equipment, output voltage, configuration, and battery age can affect actual results.
Why Online Double Conversion Matters
A standby or line-interactive UPS may require a brief transition when utility power fails. Many devices tolerate that transition, but sensitive network, security, AV, and automation equipment may still reboot, disconnect, or lock up.
An online double conversion UPS continuously powers the connected load through its inverter. This provides zero transfer time and helps isolate connected equipment from fluctuations in the incoming power supply.
Why Critical and Programmable Outlets Matter
Not every rack device has the same priority during an outage. A router, firewall, core switch, NVR, or automation processor may need to stay online longer than a streamer, display, secondary switch, or nonessential accessory.
The four always-on outlets protect critical loads until the battery is depleted. The four programmable outlets can shut down less important devices at a selected battery level, preserving more runtime for the critical equipment.
Why Extended Battery Support Matters
The internal batteries are primarily intended to cover short outages, prevent immediate shutdowns, and provide time for orderly shutdown or power restoration.
For installations that need longer runtime, the WB-UPS-OL-2000-8 supports up to five compatible WB-UPS-EBP-18AH48V extended battery packs. Smart Battery Detection recognizes connected packs and automatically adjusts the recharge rate.
Good Products to Pair With This UPS
- UPS Battery Backup to compare other UPS sizes and configurations.
- WattBox Power Solutions for related UPS, power conditioners, surge protection, and rack accessories.
- Power Management Solutions for broader backup power and equipment-protection planning.
- Smart Power Conditioners if the installation requires OvrC remote reboot or managed outlet control.
- Network Switches for wired and PoE network installations.
- Network Recorders NVRs for surveillance recording systems.
- Rack-Mount Power Strips & PDU for additional rack power-distribution planning.
Need Help Sizing the UPS?
Send us the model numbers or wattage of the devices you want to protect, your operating voltage, available circuit, and preferred runtime. We can help determine whether the WB-UPS-OL-2000-8 has enough capacity or whether a smaller, OvrC-compatible, or extended-battery configuration would be a better fit.
Key Features
2000VA online double conversion UPS for continuous clean backup power
Zero transfer time to battery for sensitive connected equipment
Pure sine wave output for reliable AV, security, and networking performance
8 outlets to protect and back up a full rack of equipment
Advanced system monitoring and configuration via included PC software
Supports up to 5 extended battery packs for longer runtime
Automatic extended battery detection and recharge optimization
Ideal for AV racks, network hardware, security systems, and structured wiring setups
5-year limited product warranty and 2-year limited battery warranty
$50,000 connected equipment guarantee
FAQ
What is the WattBox WB-UPS-OL-2000-8 used for?
It provides online double conversion battery backup for larger AV racks, network closets, NVR systems, routers, switches, control systems, computers, and other sensitive electronics.
What is its maximum capacity?
The UPS is rated at 2000VA. Its watt capacity depends on the selected output voltage. At 120V, the published maximum output is 1850W.
Is this a 2000W UPS?
Not in a typical 120V installation. The official output rating is 1930W at 125V and 1850W at 120V. The available watt capacity decreases further at lower selected output voltages.
How many outlets does it have?
It includes 8 built-in UPS-backed outlets for suitable AV, network, security, control, and computer equipment.
What are the four critical-load outlets?
Four outlets remain on until the UPS battery is depleted. They are intended for priority equipment such as routers, firewalls, switches, NVRs, storage devices, and control processors.
What are the four programmable outlets?
The four programmable outlets are protected non-critical outlets that can be configured to turn off when the battery falls to a selected percentage. This preserves more runtime for the always-on critical outlets.
What is online double conversion?
Online double conversion continuously converts incoming AC power to DC and then back to AC through the inverter. This provides conditioned output power and zero transfer time when utility power fails.
Is this a pure sinewave UPS?
Yes. It provides pure sinewave output in battery mode, making it suitable for sensitive electronics and modern power supplies.
Does it have zero transfer time?
Yes. Transfer time from AC mode to battery mode is zero because connected equipment is already being powered through the inverter.
Does this model require a 20A installation?
This is the 20A-class model. Confirm that the available circuit, receptacle, and installation are compatible before ordering. Consult a qualified electrician when electrical changes are required.
Does this model support OvrC?
This is the non-OvrC WB-UPS-OL model. It supports PC software, USB, RS-232, and optional SNMP, but it should not be presented as having the native OvrC integration of the WB-OVRC-OLUPS series.
What does the LCD show?
The LCD provides information including battery condition, estimated runtime, load, input and output voltage, frequency, current, alarms, warnings, and fault status.
Does it support graceful computer shutdown?
Yes. USB communication and the supported software can perform a graceful shutdown of a compatible computer during an extended outage.
Can I manage it over a network?
Optional SNMP support is available for compatible network-management installations. The required SNMP hardware is sold separately.
Does it have an Emergency Power Off connection?
Yes. It includes an EPO connection that can immediately shut off power to all UPS outlets when properly configured and activated.
How long will it run during an outage?
The official internal-battery chart estimates approximately 2 minutes and 26 seconds at full load, 9 minutes and 34 seconds at 50% load, 19 minutes and 17 seconds at 30% load, and 68 minutes and 23 seconds at 10% load.
Can I extend the runtime?
Yes. It supports up to five compatible WB-UPS-EBP-18AH48V extended battery packs.
How are extended battery packs connected?
The first compatible battery pack connects directly to the UPS, and additional packs can be daisy-chained. Smart Battery Detection recognizes the connected packs and adjusts the recharge rate.
Can I use it with an NVR and security cameras?
Yes. It can protect an NVR, PoE switch, router, modem, storage, and other surveillance support equipment, provided the total connected load stays within the UPS capacity.
Can I use it for routers and network switches?
Yes. Routers, switches, modems, gateways, firewalls, and network controllers are common devices to protect with this UPS.
Can I connect a large power amplifier?
Only after checking the amplifier’s actual operating, startup, and peak-current requirements. High-current amplifiers may not be appropriate even when their normal wattage appears to fit within the UPS rating.
Is it rack mountable?
Yes. It has a 2U rack-mount chassis measuring approximately 17.24 inches wide, 3.46 inches high, and 20.08 inches deep.
How much does it weigh?
It weighs approximately 42.99 lb with the internal batteries installed. Confirm that the rack and mounting hardware can safely support it.
Does the battery arrive connected?
No. The UPS ships with the internal battery disconnected for safety. Follow the official installation instructions to connect the battery before use.
Can I connect appliances, heaters, or laser printers?
No. Avoid heaters, appliances, laser printers, power tools, and other unsuitable high-draw devices. This UPS is designed for AV, networking, security, control, and computer electronics.
What should I check before ordering?
Check the total connected wattage, selected output voltage, available circuit and receptacle, runtime goal, critical-device priorities, rack depth, available 2U space, ventilation, management requirements, and whether extended battery packs will be needed.
High-Capacity Online Backup Power for Larger Equipment Racks
The WattBox WB-UPS-OL-2000-8 is a 2000VA online double conversion UPS designed for larger AV racks, network closets, security systems, structured wiring areas, control systems, and business-critical electronics that need continuous conditioned power.
It includes 8 built-in UPS-backed outlets. Four always-on critical-load outlets remain powered until the battery is depleted, while four programmable outlets can shut down non-critical equipment at a selected battery level to preserve additional runtime for the devices that matter most.
Best Use Cases
- Larger network closets: Helps protect routers, firewalls, gateways, switches, modems, controllers, and core network infrastructure.
- Security camera systems: A strong fit for NVRs, PoE switches, routers, storage devices, and surveillance support equipment.
- AV racks: Useful for processors, media servers, distribution gear, streamers, control systems, and suitable AV components.
- Smart home systems: Helps protect automation processors, hubs, bridges, controllers, and supporting network gear.
- Small business equipment: Good for offices, studios, retail locations, conference rooms, and critical equipment areas where unexpected shutdowns can interrupt operations.
- Longer-runtime projects: Supports compatible external battery packs when the internal battery runtime is not enough.
Who Should Buy This?
This UPS is a strong choice if you need to protect several rack devices directly and require more output capacity than the 1000VA or 1500VA models.
It makes sense when you need online double conversion, zero transfer time, pure sinewave output, 8 built-in outlets, critical-load prioritization, programmable load shedding, computer-based configuration, optional network management, and expandable runtime.
Who Should Not Buy This?
This is more UPS than most small modem, router, or desktop setups require. For a light equipment load, a smaller WattBox UPS may be easier to install and more cost-effective.
This is also not the right model if you specifically need native OvrC UPS monitoring or OvrC-based load shedding. This is the non-OvrC WB-UPS-OL model. It uses PC software, USB, RS-232, and optional SNMP for configuration and monitoring.
Do not assume that the 2000VA rating means the UPS supplies 2000W at every output voltage. At 120V, the published maximum output is 1850W. Leave additional headroom for runtime performance, future equipment, and startup behavior.
Do not connect heaters, appliances, laser printers, power tools, or other unsuitable high-draw equipment. High-current power amplifiers should also be evaluated carefully before connection.
Compatibility and Technical Notes
- UPS topology: Online double conversion for continuous inverter-supplied power.
- Capacity class: 2000VA.
- Output at 125V: Up to 2000VA / 1930W.
- Output at 120V: Up to 2000VA / 1850W.
- Output at 115V: Up to 2000VA / 1740W.
- Output at 110V: Up to 2000VA / 1640W.
- Output at 100V: Up to 1800VA / 1500W.
- Outlet count: Includes 8 built-in UPS-backed outlets.
- Critical-load outlets: Four always-on outlets remain active until the UPS battery is depleted.
- Programmable outlets: Four non-critical outlets can be programmed to turn off at a selected battery percentage using the PC utility software.
- Transfer time: Zero transfer time from AC operation to battery operation.
- Output waveform: Pure sinewave output in battery mode.
- Output voltage: Supports selectable output voltage settings from 100V through 127V AC.
- Current class: This is the 20A-class model. Confirm that the installation has a compatible circuit and receptacle before ordering.
- LCD monitoring: Displays load, runtime estimate, battery condition, input and output voltage, frequency, current, alarms, warnings, and faults.
- Local management: Includes PC software with USB and RS-232 connectivity.
- Network management: Optional SNMP support is available with compatible hardware sold separately.
- Emergency shutdown: Includes an Emergency Power Off connection for suitable installations.
- Graceful shutdown: USB communication can instruct a compatible computer to save files and shut down properly during an extended outage.
- Rack size: 2U rack-mount design.
- Dimensions: Approximately 17.24 inches wide, 3.46 inches high, and 20.08 inches deep.
- Weight: Approximately 42.99 lb with the internal batteries installed.
- Internal batteries: Uses four 12V / 9Ah sealed lead-acid batteries.
- Recharge time: Approximately 3 hours to recover to 95% internal-battery capacity under the specified charging conditions.
- Runtime expansion: Supports up to five compatible WB-UPS-EBP-18AH48V extended battery packs.
- OvrC: This model does not provide the native OvrC pairing functions of the WB-OVRC-OLUPS series.
Installation Considerations
Before ordering, calculate the total wattage of every device that will connect to the UPS. Use the published watt capacity for your selected output voltage and leave enough headroom for better runtime, future equipment, and changing loads.
For a typical 120V installation, plan around the published 1850W maximum rather than assuming the unit can continuously supply 2000W.
This is a 20A-class UPS. Confirm the available branch circuit, receptacle, power cord connection, and installation requirements before purchase. Consult a qualified electrician when a compatible circuit or receptacle must be added.
Decide which devices should use the four always-on critical-load outlets. The modem, router, firewall, main switch, NVR, storage, and control processor will usually be more important than secondary streamers, displays, and nonessential accessories.
Use the PC utility software to configure the four programmable outlets. Turning off non-critical equipment as the battery level falls can preserve more runtime for core network, security, and control devices.
Confirm that the rack provides 2U of space, at least 20.08 inches of chassis depth plus clearance for rear cables, proper ventilation, and enough structural support for the UPS and any extended battery packs.
The UPS ships with its internal battery disconnected for safety. The battery connection must be completed according to the official instructions before the UPS is placed into service.
Runtime Expectations
Runtime depends on the connected load. The official internal-battery runtime chart estimates approximately:
- 100% load: 2 minutes and 26 seconds
- 70% load: 5 minutes and 19 seconds
- 50% load: 9 minutes and 34 seconds
- 30% load: 19 minutes and 17 seconds
- 20% load: 31 minutes and 40 seconds
- 10% load: 68 minutes and 23 seconds
These figures are planning estimates rather than guaranteed runtime. Battery condition, temperature, connected equipment, output voltage, configuration, and battery age can affect actual results.
Why Online Double Conversion Matters
A standby or line-interactive UPS may require a brief transition when utility power fails. Many devices tolerate that transition, but sensitive network, security, AV, and automation equipment may still reboot, disconnect, or lock up.
An online double conversion UPS continuously powers the connected load through its inverter. This provides zero transfer time and helps isolate connected equipment from fluctuations in the incoming power supply.
Why Critical and Programmable Outlets Matter
Not every rack device has the same priority during an outage. A router, firewall, core switch, NVR, or automation processor may need to stay online longer than a streamer, display, secondary switch, or nonessential accessory.
The four always-on outlets protect critical loads until the battery is depleted. The four programmable outlets can shut down less important devices at a selected battery level, preserving more runtime for the critical equipment.
Why Extended Battery Support Matters
The internal batteries are primarily intended to cover short outages, prevent immediate shutdowns, and provide time for orderly shutdown or power restoration.
For installations that need longer runtime, the WB-UPS-OL-2000-8 supports up to five compatible WB-UPS-EBP-18AH48V extended battery packs. Smart Battery Detection recognizes connected packs and automatically adjusts the recharge rate.
Good Products to Pair With This UPS
- UPS Battery Backup to compare other UPS sizes and configurations.
- WattBox Power Solutions for related UPS, power conditioners, surge protection, and rack accessories.
- Power Management Solutions for broader backup power and equipment-protection planning.
- Smart Power Conditioners if the installation requires OvrC remote reboot or managed outlet control.
- Network Switches for wired and PoE network installations.
- Network Recorders NVRs for surveillance recording systems.
- Rack-Mount Power Strips & PDU for additional rack power-distribution planning.
Need Help Sizing the UPS?
Send us the model numbers or wattage of the devices you want to protect, your operating voltage, available circuit, and preferred runtime. We can help determine whether the WB-UPS-OL-2000-8 has enough capacity or whether a smaller, OvrC-compatible, or extended-battery configuration would be a better fit.
2000VA online double conversion UPS for continuous clean backup power
Zero transfer time to battery for sensitive connected equipment
Pure sine wave output for reliable AV, security, and networking performance
8 outlets to protect and back up a full rack of equipment
Advanced system monitoring and configuration via included PC software
Supports up to 5 extended battery packs for longer runtime
Automatic extended battery detection and recharge optimization
Ideal for AV racks, network hardware, security systems, and structured wiring setups
5-year limited product warranty and 2-year limited battery warranty
$50,000 connected equipment guarantee
What is the WattBox WB-UPS-OL-2000-8 used for?
It provides online double conversion battery backup for larger AV racks, network closets, NVR systems, routers, switches, control systems, computers, and other sensitive electronics.
What is its maximum capacity?
The UPS is rated at 2000VA. Its watt capacity depends on the selected output voltage. At 120V, the published maximum output is 1850W.
Is this a 2000W UPS?
Not in a typical 120V installation. The official output rating is 1930W at 125V and 1850W at 120V. The available watt capacity decreases further at lower selected output voltages.
How many outlets does it have?
It includes 8 built-in UPS-backed outlets for suitable AV, network, security, control, and computer equipment.
What are the four critical-load outlets?
Four outlets remain on until the UPS battery is depleted. They are intended for priority equipment such as routers, firewalls, switches, NVRs, storage devices, and control processors.
What are the four programmable outlets?
The four programmable outlets are protected non-critical outlets that can be configured to turn off when the battery falls to a selected percentage. This preserves more runtime for the always-on critical outlets.
What is online double conversion?
Online double conversion continuously converts incoming AC power to DC and then back to AC through the inverter. This provides conditioned output power and zero transfer time when utility power fails.
Is this a pure sinewave UPS?
Yes. It provides pure sinewave output in battery mode, making it suitable for sensitive electronics and modern power supplies.
Does it have zero transfer time?
Yes. Transfer time from AC mode to battery mode is zero because connected equipment is already being powered through the inverter.
Does this model require a 20A installation?
This is the 20A-class model. Confirm that the available circuit, receptacle, and installation are compatible before ordering. Consult a qualified electrician when electrical changes are required.
Does this model support OvrC?
This is the non-OvrC WB-UPS-OL model. It supports PC software, USB, RS-232, and optional SNMP, but it should not be presented as having the native OvrC integration of the WB-OVRC-OLUPS series.
What does the LCD show?
The LCD provides information including battery condition, estimated runtime, load, input and output voltage, frequency, current, alarms, warnings, and fault status.
Does it support graceful computer shutdown?
Yes. USB communication and the supported software can perform a graceful shutdown of a compatible computer during an extended outage.
Can I manage it over a network?
Optional SNMP support is available for compatible network-management installations. The required SNMP hardware is sold separately.
Does it have an Emergency Power Off connection?
Yes. It includes an EPO connection that can immediately shut off power to all UPS outlets when properly configured and activated.
How long will it run during an outage?
The official internal-battery chart estimates approximately 2 minutes and 26 seconds at full load, 9 minutes and 34 seconds at 50% load, 19 minutes and 17 seconds at 30% load, and 68 minutes and 23 seconds at 10% load.
Can I extend the runtime?
Yes. It supports up to five compatible WB-UPS-EBP-18AH48V extended battery packs.
How are extended battery packs connected?
The first compatible battery pack connects directly to the UPS, and additional packs can be daisy-chained. Smart Battery Detection recognizes the connected packs and adjusts the recharge rate.
Can I use it with an NVR and security cameras?
Yes. It can protect an NVR, PoE switch, router, modem, storage, and other surveillance support equipment, provided the total connected load stays within the UPS capacity.
Can I use it for routers and network switches?
Yes. Routers, switches, modems, gateways, firewalls, and network controllers are common devices to protect with this UPS.
Can I connect a large power amplifier?
Only after checking the amplifier’s actual operating, startup, and peak-current requirements. High-current amplifiers may not be appropriate even when their normal wattage appears to fit within the UPS rating.
Is it rack mountable?
Yes. It has a 2U rack-mount chassis measuring approximately 17.24 inches wide, 3.46 inches high, and 20.08 inches deep.
How much does it weigh?
It weighs approximately 42.99 lb with the internal batteries installed. Confirm that the rack and mounting hardware can safely support it.
Does the battery arrive connected?
No. The UPS ships with the internal battery disconnected for safety. Follow the official installation instructions to connect the battery before use.
Can I connect appliances, heaters, or laser printers?
No. Avoid heaters, appliances, laser printers, power tools, and other unsuitable high-draw devices. This UPS is designed for AV, networking, security, control, and computer electronics.
What should I check before ordering?
Check the total connected wattage, selected output voltage, available circuit and receptacle, runtime goal, critical-device priorities, rack depth, available 2U space, ventilation, management requirements, and whether extended battery packs will be needed.
RELATED PRODUCTS
Discover Other Products You Might Like and Simplify Your Search
Why Customers Keep Coming Back
Real feedback from customers nationwide on our service, shipping, and support.

M. from New Jersey
Outstanding customer service speakers arrived cross country Cali to New Jersey in spectacular condition.
Great communication great packaging would buy again.

R. from California
Easy ordering and super fast standard shipping. Great experience and highly recommended.

G. from Texas
Place a large order and was able to accommodate me quickly and parts were delivered as promised

M. from Louisiana
Product arrived quickly and in good condition. The price was very competitive. I’m very satisfied. I highly recommend the seller.

B. from Texas
Arrived promptly & in excellent condition with all required parts. Sounds great and impedance matches other speakers.

S. from Florida
Excellent customer service! Picks up the phone. Fast delivery across the country. Worthy online retailer!

G. from Texas
Bear Security Shop has a great customer service, and is fast and easy to do business with. I've ordered product from them twice with great service both times. Would definitely recommend them.

J. from Los Angeles
Excellent customer service. Lightning fast shipping. Very grateful for the team at Bear Security. Thank you!

T. from Oklahoma
Trustworthy, honest, and plus integrity, with outstanding professionalism! I highly recommend them buy with confidence!

C. from Colorado
Experience with Bear Security Shop was fast and easy and the speakers arrived less than we week after ordering. And the price was half what my installer wanted to charge me for these speakers. Highly recommended.

V. from California
Excellent communication. Prompt responses and very knowledgeable and helpful. Items arrived faster than expected and in brand new condition as described. Will continue to do business with them.

C. from South Dakota
Awesome camras well worth the money good seller would buy again 👍
Get Expert Picks and Real Setup Advice
Subscribe for practical tips, product recommendations, and occasional subscriber only deals. No spam.